Products

We currently offer three
of the finest Coleman® Mach®
A/C units for the best price.
And we are ready to ship internationally!

Click on any brochure page below for details.
or
Click here to view the Data Inquiry Sheet.

The ROUGHNECKTM
International Air Conditioner

This unit is built tough to handle the jarring and vibrations of off road terrain and heavy machinery.

240 VAC, 50 Hz, 1 Phase

The MACH 3 PLUSTM
International Air Conditioner

The world's most popular R.V. A/C unit.

115 VAC, 60 Hz, 1 Phase

The SEAMACHTM
Marine Air Conditioner

Built to handle salt water environments. Perfect for houseboats.

115 VAC, 60 Hz, 1 Phase

.

A Division of AIRXCEL, Inc.
DATA INQUIRY SHEET
8373B896 MACH 3+
8473B896 ROUGHNECK
INTERNATIONAL SERIES
WITH R-407C
Capacity (Nominal BTUH) Cooling - Output BTU ..... 13,500
Heating - Output BTU1 ...... 5,600
Electrical Rating 240 VAC, 50 HZ, 1 Phase
Cooling Full Load AMP's at A.R.I. Standard Condition Compressor ..... 6.2
Fan Motor ....... 0.8(Low), 1.2(High)
Total ................ 7.0(Low), 7.4(High)
Feature Equipment Amps Heating1 ..... 9.0
Running Watts: (Cooling) A.R.I. Standard Condition
(80 F. DB/67 F. WB Indoor, 95 F. DB Outdoor)
1687
Running Watts: (Cooling) A.R.I. Maximum Condition
(95 F. DB/71 F. WB Indoor, 115 F. DB Outdoor)
2117
Running Watts: (Heating)1 1800
Compressor Locked Rotor Amps 32.0
Thermostat Temperature Range Cooling  - 61 F. (+/- 5)
Heating1 - 85 F. (+/- 5)
Metering Device Capillary Tube
Refrigerant Charge 8373A - 12.75 oz.
8473A - 15.00 oz.
Evaporator Air Delivery (CFM) 300 CFM - High Speed
Generator Size See "Generators" Below
Unit Weight (pounds) - Heat/Cool 95.02
Use time delay fuse or circuit breaker (U.L. H.A.C.R. Type C.S.A.) Rated at 15 amps.
Supply wires 12 AWG MIN. (copper)
1When equipped with Elect-A-Heat feature.
2Ceiling assemblies may add an additional 3.5 to 12.5 pounds depending on the model number.

CEILING ASSEMBLY: 8370-715

GENERATORS:
It is not the policy of RV Products to size generators for application in Recreation Vehicles or
related structures. However, when sizing generators, the total electrical power consumption in
Watts must be determined and taken into consideration, such as:
A. Maximum running watts of the air conditioner at A.R.I.
maximum operating conditions (See Specifications).
B. Power consumption of electronic ovens, toasters, coffee
makers, television sets, refrigerators, lights, etc.
C. Generators do lose capacity under the following conditions:
(1) altitude increases above sea level, (2) temperature
increases above certain outdoor design temperatures and
(3) lack of maintenance.

RV Products
A Divisioin of Airxcel, Inc.
P.O. Box 4020
Wichita, KS 67204


All Contents Copyright © 2003, GlobalRooftopAir.com
All Rights Reserved